Title: HEAT PIPE SCREEN WICK MODELLING
Authors: UNGUREANU, Virgil Barbu
Keywords: heat pipe
screen wick
porosity
capillarity
pore radius
Issue Date: Oct-2010
Publisher: Transilvania University Press of Braşov
Citation: GOOGLE SCHOLAR
Series/Report no.: COMAT 2010;230-235
Abstract: Generally, an optimal wick structure require a small surface pores for large capillary pressure, but large internal pores for minimal liquid flow resistance. Screen wicks are most available, because the possibility of their arrangement in different manner on the heat pipe inner wall. The below discussed properties of the wick are the porosity and the effective pore radius based on a geometric model