DSpace at Transilvania University >
Civil Engineering >
Research Paper >
Please use this identifier to cite or link to this item:
http://hdl.handle.net/123456789/1776
|
Title: | SOFWARE OPTIMIZATION OF A TECHNOLOGICAL SOLUTION FOR WATERPROOFING REHABILITATION OF RISING DAMP AFFECTED WALLS |
Authors: | FLORIN-L TAMAS., IOAN TUNS |
Keywords: | anchoring wedges rising damp price insulation sheet moisture |
Issue Date: | Nov-2011 |
Abstract: | The drainage practice of buildings affected by capillary moisture
represents a complex issue and allows a technical approach from multiple points of view.
In old buildings (such as castles, cathedrals, churches) was found in many cases an
increase of capillary moisture at basement and foundations level, with consequences in
degradation of finishes, plaster and even walls. Several causes that have led to these
deficiencies are: heating some areas that were design to work unheated, different
construction works that created barriers to the moisture movement, the raise of water
table or inadequate work for rainwater capture and removal process. The aim of this
article is, on the one hand, to present a brief technological description of a system which
allows the complete removal of rising damp phenomenon in walls, and on the other hand,
to provide users with a software application in order to facilitate the analysis from
theoretical point of view of multiple choices for method implementation, as well as
practical approach, in terms of expressing the cost of intervention. |
URI: | http://hdl.handle.net/123456789/1776 |
ISSN: | 2248-0293 |
Appears in Collections: | Research Paper
|
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
|