Title: STUDY ON THE SCREEN SEALING CHARACTERISTICS EXECUTED AT MILEANCA DAM (CASE STUDY)
Authors: A. NICU, C. NICU
N. FLOREA
Keywords: screen sealing,
self-hardening mud,
guiding beams,
bentonite suspension,
impermeable layer (clay marl).
Issue Date: 2015
Publisher: Transilvania University Press Brasov
Abstract: Using the solution of self-hardening mud to complete the Mileanca dam screen sealing has stopped the infiltration of water through the permeable layers. The screen seal has a width of 60 cm and a variable depth H = 7 to 11 m. It is embedded in the shale layer, to a depth of 1 m. The work was done by respecting the technology and the self-hardening mud recipe was established after laboratory assessment and land verification with the consent of the engineer and the beneficiary.
URI: http://hdl.handle.net/123456789/2026
ISSN: 2285-7656
Appears in Collections:CIBv2015

Files in This Item:

File Description SizeFormat
20_Nicu C._Nicu N._Florea.pdf1.02 MBAdobe PDFView/Open

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2010  Duraspace - Feedback